Zephyr Ventilation Hood AK8100S User Manual

Important Safety Notice  
Read and save these instructions  
Use, Care and Installation Guide  
Read all Instructions before Installing and operating this appliance  
Important Safety Notice  
d.  
Use an extinguisher ONLY if:  
1. You know you have a Class ABC extinguisher, and you already know how  
to operate it.  
AK8000AS, AK8100S, AK8200S  
MODEL:  
READ AND SAVE THESE INSTRUCTIONS  
2. The fire is small and contained in the area where it started.  
3. The fire department is being called.  
4. You can fight the fire with your back to an exit  
WARNING  
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS  
FAN WITH ANY SOLID-STATE CONTROL DEVICE.  
WARNING  
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:  
WARNING  
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO  
PERSONS, OBSERVE THE FOLLOWING:  
a. Installation work and electrical wiring must be done by qualified person (s) in  
accordance with all applicable codes and standards. Including fire-rated construction.  
b. Sufficient air is needed for power combustion and exhausting of gases through the  
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating  
equipment manufacturer’s guideline and safety standards such as those published  
by the National Fire Protection Association (NFPA) and the American Society for  
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code  
authorities.  
a. Use this unit only in the manner intended by the manufacturer, if you have questions,  
contact the manufacturer.  
b. Before servicing or cleaning unit, switch power off at service panel and lock panel  
to prevent power from being switched on accidentally. When the service disconnecting  
means cannot be locked, securely fasten a prominent warning device, such as a tag,  
to the service panel.  
c. When cuttig or drilling into wall or ceiling, do not damage electrical wiring and other  
hidden utilities.  
d. Ducted fans must always vent to the outdoors.  
CAUTION  
For general ventilating use only. Do not use to exhaust hazardous or explosive materials  
and vapors. Take care when using cleaning agents or detergents.  
Suitable for use in household cooking area.  
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate  
for the application and be connected to a GFCL (Ground Fault Interrupter protected  
branch circuit).  
WARNING  
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:  
a. Never leave surface units unattended at high settings. Boilovers cause smoking  
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.  
b. Always turn hood ON when cooking at high heat or when flaming food  
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate  
g. NEVER place a switch where it can be reached from a tub or shower.  
h. Make sure the power is off before installing, wiring or maintenancing.  
WARNING  
on fan or filter.  
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.  
d. Use proper pan size. Always use cookware appropriate for the size of the surface  
element.  
e. Keep fan, filters and grease laden surfaces clean.  
f. Use high setting on hood only when necessary.  
g. Don’t leave hood unattended when cooking.  
h. Always use cookware and utensils appropriate for the type of and amount of food  
being prepared.  
CAUTION  
To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into  
spaces within walls, ceilings, attics, crawl spaces or garages.  
WARNING  
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN  
ISOLATING WALL CONTROL/SWITCH.  
WARNING  
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP  
FIRE, OBSERVE THE FOLLOWING:  
OPERATION  
Always leave safety grills and filters in place. Without these components, operating  
blowers could catch onto hair, fingers and loose clothing.  
a.  
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then  
turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out  
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  
work.  
b.  
c.  
NEVER PICK UP A FLAMING PAN – You may be burned.  
DO NOT USE WATER, including wet dishcloths or towels – a violent steam  
explosion will result.  
JAN07.0201  
 
INSTALLATION  
INSTALLATION  
DUCTING  
SPECIFICATIONS  
Twister (AK8000AS)  
WARNING FIRE HAZARD  
5-15/16”  
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or  
garages. All exhaust must be ducted to the outside.  
Use Metal ductwork only.  
Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.  
Some Ducting Options:  
side wall cap  
w/ gravity damper  
4-3/32”  
side wall cap  
w/ gravity damper  
BACK  
Soffit or crawl space  
Roof Pitch w/  
Flashing & Cap  
FRONT  
C/L  
10-5/8”  
(cut out)  
cut out dimension  
26-7/8”  
(cut out)  
= cut out dimension  
Page 2  
 
Page 3  
INSTALLATION  
INSTALLATION  
SPECIFICATIONS  
SPECIFICATIONS  
Tornado 1 unit (AK8100S)  
Tornado 2 unit (AK8200S)  
33-7/16"  
26-19/32”  
16-3/16"  
11-3/16”  
10-5/16”  
15-9/32”  
27-9/16”  
34-7/16”  
9-27/32”  
7-7/8”  
2-3/8"  
2-13/16"  
27-9/16”  
34-7/16  
1-3/8”  
5-1/8”  
2”  
1/2" Elec. K.O.  
6"  
1/2"Elec. K.O.  
8"  
11-3/16”  
16-3/16"  
10”  
C/L  
C/L  
10-5/8”  
(cut out)  
cut out dimension  
15-3/8”  
(cut out)  
cut out dimension  
26-7/8”  
(cut-out)  
= cut out dimension  
33-1/2”  
(cut out)  
= cutout dimension  
 
Page 4  
Page 5  
INSTALLATION  
CONTROLS & FEATURES  
INSTALLATION  
CONTROLS & FEATURES (AK8100S/AK8200S)  
Front View  
Ductwork  
Mounting the Range Hood  
1. Determine and mark the mounting  
position of the range hood with a pencil.  
wood frame  
wood frame  
2
1 Speed Selection  
Lights On/Off  
2. Cut out the opening where the range  
hood will be installed.  
3. Cut out wall or ceiling area for clearance  
of ductwork. Install ductwork prior to  
range hood.  
4. Determine location for the power  
supply cable. After drilling access hole,  
rout the cable into the electrical box  
of the range hood. Secure with a cable  
lock and connect to range hood  
electrical system.  
Controls  
Power supply cable  
Locking clip  
Entry into range hood  
1
Speed Selection  
Side View  
This switch controls the speed of the blower. The first position is low speed,  
the second is medium speed, and the third is high speed.  
wood frame  
wood frame  
5. Position range hood into location and  
ensure spring locking clip has locked  
into position.  
2 Lights On/Off  
6. Fasten wood screws into wood frame  
Turn lights on or off by moving this switch.  
opening via the long side. Wood blocking  
may be necessary if wood frame is too thin.  
ELECTRICAL  
WARNING  
wood  
blocking  
CONTROLS & FEATURES (AK8000AS)  
Attach 2 screws to each  
long side of AK8100/AK8200  
All Electrical work must by performed by qualified electrician or person with similar technical  
know how and background.  
Lights Bright / Dim / Off  
For personal safety, remove house fuse or open circuit breaker before beginning installation.  
Do not use extension cord or adapter plug with this appliance.  
III II  
I
0
II  
I
0
Follow National electrical codes or prevailing local codes and ordinances.  
Electrical Supply:  
This appliance requires a 120V 60Hz electrical supply., and connected to an individual, properly  
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring  
must be 2 wire w/ ground. Please also refer Electrical Diagram labeled on product.  
1
Speed Selection  
This switch controls the speed of the blower. I is low speed,  
I I is medium speed, and I I I is high speed.  
Cable Lock:  
A cable locking connector (not  
supplied) might also required by  
local codes. Check with local  
requirements and codes, purchase  
and install appropriate connector if  
2 Lights Bright / Dim / Off  
This switch controls the lights. Slide switch to I for dim lighting and I I for bright lighting,.  
necessary.  
Cable Lock  
 
Page 6  
Page 7  
MAINTENANCE  
MAINTENANCE  
CLEANING (AK8100S, AK8200S)  
CLEANING (AK8000AS)  
Models AK8100S and AK8200S hoods are designed with a self cleaning feature.  
The centrifigal blower system automatically liquefies cooking residue accumulated  
in its internal housing and deposits the residue in the residue cups. Nevertheless,  
grease from cooking can also dry and adhere in the internal housing. Running the  
self clean function periodically will flush out accumulated residue in the range  
hood’s internal housing.  
The AK8000AS metal mesh filter fitted by the factory is intended to  
filter out residue and grease from cooking. It need not be replaced  
on a regular basis but is required to be kept clean.  
Filter should be cleaned every 30 days based on a usage of 1 hour  
per day. Clean filter more often if performance decreases.  
Cleaning should be completed approximately once a month under normal use.  
Non corrosive, non abrasive grease cutting spray detergents are recommended.  
Remove and clean by hand or in dishwasher on low setting. Or spray  
degreasing detergent and leave to soak if heavily soiled.  
Self Cleaning Instructions:  
Dry filter and re-install before using hood.  
Remove safety grilles by unscrewing the thumb screw on each grille.  
Turn blowers on lowest speed for cleaning.  
Should filter wear out due to age and prolonged use, contact the  
manufacturer.  
With nozzle on spray, squirt grease cutting detergent directly onto blower blades  
10 - 15 times. (Do not use oven cleaner)  
Allow self cleaning to complete for 5 minutes, turn blower off.  
Remove residue cups. Clean with mild detergent or in dishwasher.  
Re-install residue cups and safety grilles before using hood.  
SURFACE MAINTENANCE (AK8000AS, AK8100S, AK8200S)  
Clean periodically with hot soapy water and clean cotton cloth. Do not use  
corrosive or abrasive detergent or steel wool/scouring pads which will scratch  
and damage surface.  
For heavier soil use liquid degreaser. Do not use any product containing  
chlorine bleach. Do not use “orange” cleaners.  
Slide off to remove  
residue cups  
 
Page 9  
Page 8  
MAINTENANCE  
LIGHTS  
Replacing Light Bulbs  
CAUTION: Light bulb becomes extremely hot when turned on.  
DO NOT touch bulb until switched off and cooled. Touching hot  
bulbs could cause serious burns.  
Make sure all power is turned off and  
bulbs are not hot.  
Remove by turning bulb counter  
clockwise.  
If bulbs are difficult to turn due to  
prolonged use, firmly attach a glass  
suction cup approx. the diameter of the  
bulb and turn.  
Replacement bulbs are available at  
specialty lighting stores. Purchase type  
GU-10 120V 35W halogen bulbs.  
Or to order bulbs, please call our service  
center: 888-880-8368or online parts store:  
 
Page 10  

Whirlpool Air Conditioner BHAC0600BS0 User Manual
Whirlpool Ice Maker ECKMF 86 User Manual
Whirlpool Washer Dryer LA609OXS User Manual
Whirlpool Washer Dryer LA5380XM User Manual
Wolf Appliance Company Ventilation Hood PW362418 User Manual
Yamaha Guitar AEX502 User Manual
Zanussi Refrigerator ZRB 7821 User Manual
Zanussi Washer Dryer Z188A User Manual
Zanussi Washer ZWF 1010W User Manual
Zenoah Brush Cutter BC2310LE User Manual